LifeStar Owner’s Manual - 6 -
Section 4: Specifications
Inverter
20
-
1050CUL
-
DC
20
-
-
DC
Output at 120 VAC RMS (Continuous Power Rating) 1050 Watts
Surge Capacity at 120 VAC (3 sec) 2100 Watts
Input Voltage, VDC
(Deep Cycle Battery Recommended)
12 VDC, Nominal
10.5 VDC min, 16.0 VDC max.
AC Output Voltage
120 VAC ± 5%
DC Current Draw (Battery)
OFF 0.017 Amps Typical
In Load Demand 0.09 Amps Typical
Full ON at No AC Load 0.7 Amps Typical
Full On with Load
Approx. AC Load Watts ÷ 10
Frequency
60 Hz ± 0.2%
Output Wave Form Modified Sine Wave
Battery Charger
Charging Capacity (note “DC Source” section below)
55 Amps (High)
15 Amps (Low)
N/A
Input Voltage
120 VAC ± 10%
N/A
Input Current 12.0 Amps N/A
Bulk Voltage
14.2 VDC (flooded), 14.1 VDC
(gel)
N/A
Float Voltage
13.2 VDC (flooded), 13.6 VDC
(gel)
N/A
Bypass Transfer
Output Current, GFCI Outlet 12 Amps
DC Source
Output Voltage Battery Voltage
Output Current
20.0 Amps Max. (Current must be subtracted from
“Charging Capacity” above)
Other Specifications
AC Input Termination 3ft. Line Cord
AC Output Termination Duplex GFCI Receptacle
Ambient Temperature
-20° to +110°F, -29° to +43.4°C
Cooling Air Fan Cooled
Chassis Aluminum
Dimensions 11.57”W x 5.94”H x 11.04”D
Weight 22 LBS